Swissmade
NEWS
Mar 23, 2023
MEASUREMENT

MAGPy2 – A Performance Boost

MAGPy customers can rejoice: SPEAG has released MAGPy2, which includes a redesigned probe and extended software. MAGPy2 guarantees accurate extrapolation of incident fields to the probe surface, support of pulsed and multifrequency signals, and estimates of all basic restriction quantities required by regulators. MAGPy2 is fully compatible with IEC/IEEE 63184:2023 and meets all the latest FCC and ISED requirements. MAGPy2 can also be used as part of the measurement system DASY8/6 Module WPT V2.0. 

SPEAG released the first version of MAGPy in June 2021. It was designed to carry out reliable in situ compliance testing in the near field of wireless power transfer (WPT) systems or in the close vicinity of high-current industrial installations. The system is the most advanced device on the market, i.e., the only handheld device that reliably estimates basic restriction quantities and that is compatible with IEC/IEEE 63184:2023 Tier 3.

2303 MAGPy02 web

But we wanted to make the system even better, so we have redesigned the probe and extended the software to further boost its performance and its compatibility with the latest regulatory requirements. MAGPy2 with software V2.0 has major benefits:

  • Measuring closer to the source (7.5 mm vs 20.0 mm) and hence providing much more accurate and reliable extrapolation to the surface of the probe; this empowers field evaluations on the surface of the device under test, as required by FCC (TCB Workshop in April 2022) and ISED (RSS-102 SPR-002 Issue 2 published in October 2022);
  • Evaluation of periodic signals with non-sinusoidal waveforms and duty cycles, thanks to the implementation of the multifrequency processing algorithm and the peak detection function;
  • Addition of new basic restriction quantities, i.e., local induced electric (E-) field (required by ISED) and 1 g averaged specific absorption rate (SAR; required by FCC and ISED);
  • Dual usage of the system as a hand-held system (MAGPy2) and as part of Module WPT (DASY8/6 Module WPT V2.0), resulting in acceleration of the measurement by almost a factor of 8 and additional incident E-field evaluations compared to the first version.

Advantages Compared to Competitive Devices

MAGPy2 is optimized for taking precise measurements of the incident field and the induced fields in the near field of sources:  

  • Its magnetic field sensor has an active area of only 1 cm2 as required by IEC/IEEE 63184:2023 for precise measurements;
  • The close distance of the measurement sensors to the probe surface combined with gradient information empowers accurate extrapolation to the probe surface;
  • It is the only device able to estimate the following induced field quantities for Tier 3 assessment as specified in IEC/IEEE 63184:2023 using the gradient information from the 27 sensors:
    • maximum induced E-field averaged over 8 mm3 (e.g., ICNIRP 2010, ICNIRP 2020)
    • maximum induced E-field averaged over 5 mm (e.g., IEEE C95.1-2019)
    • maximum local induced E-field (e.g., HC Safety Code 6)
    • maximum induced current density averaged over 1 cm2 (e.g., ICNIRP 1998)
    • peak SAR averaged over 1 g of tissue (e.g., FCC, HC Safety Code 6)
    • peak SAR averaged over 10 g of tissue (e.g., ICNIRP 1998, ICNIRP 2020, IEEE C95.1-2019)
  • The evaluation of the basic restriction using the gradient information reduces overestimation of the compliance values by up to 40 dB in the near field of sources compared to standard isotropic probes (a factor of 100 for E-field and current density and a factor of 10,000 for SAR);
  • It allows entire recorded measurement sessions to be replayed, including post-measurement analyses and evaluations;
  • It can be upgraded to DASY8/6 Module WPT V2.0 for dual usage without hardware replacement and new calibration.

The video shows a first glimpse of the new probe design and the new features of MAGPy2. 

Applications

MAGPy2 is optimized for in situ exposure and compliance evaluations at any location, including:

  • Automotive/vehicular/train wireless power transfer;
  • Industrial and utility (e.g., industrial welding, induction cooking, electronic article surveillance, and WPT);
  • Energy supply (e.g., installations and operators of WPT networks);
  • Ubiquitous devices equipped with WPT technologies (e.g., mobile phones, implantable medical devices, wearable devices, and Internet of Things);
  • High power/current electromagnetic sources.
     

To receive a quotation and for further information, please contact us at info@speag.swiss or via any of our sales channels.

 

SIMULATION

Sep 2, 2011

Contact
semx-support@speag.swiss

 

SEMCAD X v14.6.2 Update Release

The SEMCAD X Team is pleased to announce the release of SEMCAD X v14.6.2, an update of SEMCAD X Aletsch v14.6.

 
SIMULATION

Aug 26, 2011

Contact
semx-support@speag.swiss

 

SEMCAD X Light v14.6.2 Release

The SEMCAD X Team is pleased to announce the release of SEMCAD X Light V14.6.2, a limited version of SEMCAD X v14.6.2 Aletsch.

 
SIMULATION

Jul 21, 2011

Contact
semx-support@speag.swiss

 

SEMCAD X v14.6.1 Release

The SEMCAD X Team is pleased to announce the release of SEMCAD X v14.6.1, an update of SEMCAD X Aletsch v14.6.

 
SIMULATION

Jun 29, 2011

Contact
semx-support@speag.swiss

 

SEMCAD X Student Research Award 2010 Winners

Schmid & Partner Engineering AG (SPEAG) is very pleased to announce the winners of SEMCAD X Student Research Award 2010.

 
MEASUREMENT

Jun 20, 2011

Contact
info@speag.swiss

 

iSAR Quad Release

iSAR Quad is officially released! iSAR Quad is the largest and highest-resolution iSAR available. iSAR Quad is well suited for scanning laptops, tablet computers and other large devices. It also improves the precision for SAR evaluations of devices operating above 3 GHz. We provide an upgrade option from iSAR Flat to iSAR Quad.

 
MEASUREMENT

May 25, 2011

Contact
info@speag.swiss

 

DASY52 V6.2 and SEMCAD X V14.4.5 Software Release

The DASY team is pleased to announce the release of DASY52 V6.2 (482) and SEMCAD-X V14.4.5 (3634). We recommend the immediate installation of this upgrade as it addresses reported bugs and various minor requests/ suggestions by our customers.

 
SIMULATION

May 13, 2011

Contact
semx-support@speag.swiss

 

Desmond Yeo Wins 1st Prize Engineering Poster at ISMRM 2011

Desmond Yeo, from GE Global Research, wins the 1st price in the Engineering Poster Session with poster #1811 using SEMCAD X:

INVESTIGATION OF A DUAL-FUNCTION APPLICATOR FOR RF HYPERTHERMIA AND MRI

 
SIMULATION

May 5, 2011

Contact
semx-support@speag.swiss

 

SEMCAD X V14.6.0 Aletsch

The SEMCAD X Team is pleased to announce the release of SEMCAD X V14.6.0 Aletsch, a major upgrade offering a range of powerful new Modules and features, more robust handling as well as new customization options.

 
MEASUREMENT

Apr 22, 2011

Contact
info@speag.swiss

 

Improved Broad-Band Liquids

SPEAG completed its development of greatly improved head and body tissue simulating liquids for the frequencies from 3500 to 5800 MHz. This new broad-band liquids are within ±5% to the target values and provide significantly improved long-time stability and reduction of the maintenance efforts. Therefore, they lower costs and improve reproducibility of the test results.

 
MEASUREMENT

Apr 14, 2011

Contact
info@speag.swiss

 

iSAR Quad pre-release

iSAR Quad is the largest and highest-resolution iSAR available. iSAR Quad is capable of scanning a 600 mm x 400 mm planar area with a 1 mm resolution, making it well suited for scanning laptops, tablet computers and other large devices. 

 
Page 28 of 33
 
 
Latest News