DASY8/6 Module HAC V1.2: Packed with New Features

Simplified procedures, additional viewer options, and more: SPEAG has further improved the user experience when testing compatibility with DASY8/6 Module HAC V1.2 between a wireless device and hearing aids according to ANSI C63.19-2019.

After the successful launch of the first version of our hearing aid compatibility module, DASY8/6 Module HAC V1.0, in November 2021, SPEAG has further improved the features and workflow of the module based on valuable customer feedback. Streamlined procedures and improved visualizations now make it easier and smoother to demonstrate compliance with ANSI C63.19-2019.

Compatibility with Windows 10/1

Module HAC V1.2 supports the latest hardware revision of the Audio Magnetic Measurement Instrument (AMMI). Based on the Roland Rubix22 USB audio interface, it is fully compatible with Windows 10/11.

Simplified Procedure

In Module HAC V1.2, the hearing aid compatibility test arch position and probe calibration results are persistent. It is no longer necessary to import them after restarting the Jupyter notebook – the last used values are automatically restored.

AngleCalibration

System response during probe angle determination

 

Automated Calculation of Codec / System Delay

The audio signal emitted by the wireless device under test may be delayed due to the codec latency. In Module HAC V1.2, this parameter no longer needs to be evaluated manually: it is now determined automatically in post-processing.

Additional Viewer Options

The field viewer comes with many new features: for example, users can now edit the color bar range and export all displayed data. In addition, the spectrally weighted undesired magnetic noise can now be visualized.

FieldViewer

H-field distribution for a Telephone Magnetic Field Simulator (TMFS) measured in transverse orientation. The color bar range is editable

 

Intuitive Communication System User Interface

The communication system selection has also been further improved: the layout is more user-friendly and the most frequently used test channels (low/middle/high) are more prominently highlighted.

CommunicationSystems

Selection of the communication system to be measured

 

Improved Post-Processing of Undesired Audio Band Magnetic Field

The post-processing algorithm for evaluating the undesired magnetic field in the audio band has been improved to avoid overestimation of when low-frequency components dominate.

 

DASY8/6 Module HAC V1.2, together with the updated manuals, can be downloaded here.

Your feedback helps us to constantly improve our products and services. If you have thoughts and suggestions, please reach out to us at support@speag.swiss.

For further information on DASY8/6 Module HAC V1.2 or any of our other products, please contact us at info@speag.swiss or via any of our sales channels.

 

MEASUREMENT

May 30, 2017

Contact
info@speag.swiss

 

Commercial Release of IEC 62209-3 Validation Antennas

Validation sources enable independent evaluation of the performance of specific absorption rate (SAR) measurement systems, in accordance with draft IEC 62209-3.

 
MEASUREMENT

May 17, 2017

Contact
info@speag.swiss

 

Major cDASY6 Release: V6.4

SPEAG is announcing the Beta-Release of cDASY6.4 that offers a multitude of assets and improvements, expanding the existing capabilities of DASY52. At the same time, it is already fully compatible with the upcoming standard IEC 62209-U. The final release will become available on June 20th, 2017.

 
CORPORATE

May 16, 2017

Contact
info@speag.swiss

 

SPEAG & ZMT Workshops in China and Taiwan in June 2017

Schmid & Partner Engineering AG (SPEAG) and ZMT Zurich MedTech AG (ZMT) are pleased to announce their annual hardware & software workshops which will be held in Beijing, Shanghai and Shenzhen (China), as well as Taipei (Taiwan) in June 2017. On a number of occasions, our in-house experts, together with our partners from the Auden Techno. Corp., will demonstrate SPEAG's and ZMT's latest innovations and product updates, and inform about standard trends and our roadmap going forward to address industry needs.

 
MEASUREMENT

May 10, 2017

Contact
info@speag.swiss

 

5G Module Beta Release

New Beta-version enables power density compliance testing as close as 2 mm from any surface with minimal uncertainty.

 
MEASUREMENT

Apr 25, 2017

Contact
info@speag.swiss

 

UL Invests Into More Effective SAR Testing

PC World has published a video by Underwriters Laboratories Inc. (UL) last week demonstrating their latest fleet of DASY6 systems.

 
MEASUREMENT

Apr 18, 2017

Contact
info@speag.swiss

 

SAR Compliance Testing of Wireless Devices with Time-Averaged Power Control

A user video demonstrates the new time-averaged SAR feature of cDASY6 V6.4.

 
MEASUREMENT

Apr 13, 2017

Contact
info@speag.swiss

 

cSAR3D is the Chosen Solution in Egypt

A cSAR3D system was recently delivered and installed at the Egyptian National Telecom Regulatory Authority in Cairo.

 
MEASUREMENT

Apr 4, 2017

Contact
info@speag.swiss

 

SPEAG’s & CTIA’s New Forearm Phantom SHO-GFPC-V1

Standardized Over-The-Air (OTA) evaluation of wrist-worn devices in a precise and repeatable fashion.

 
MEASUREMENT

Mar 14, 2017

Contact
info@speag.swiss

 

New OTA Phantom Optimized for Testing Head-Mounted Wearables

SPEAG’s new OTA phantom SAM V4.6BSE provides maximum flexibility for testing wearable devices mounted to the head.

 
MEASUREMENT

Mar 7, 2017

Contact
info@speag.swiss

 

Quick cSAR3D Measurement of Wireless Device

Fast SAR measurements are easier than ever! Watch a new user video demonstrating the features of cSAR3D V2.8.

 