Swissmade
NEWS
19/02/2019
MEASUREMENT

Release of cDASY6 Module mmWave V1.6

SPEAG’s latest software release incorporates many new features and improvements to facilitate power compliance testing of devices operating >10 GHz

With cDASY6 Module mmWave V1.6, power density compliance testing is now easier than ever:

  • A new Generic Scan that allows determination of the power density with the far-field approximation based on a single plane measurement has been added. Now, assessments valid in the far-field and quasi-far-field are much faster compared to generally valid 2-plane method with phase reconstruction
  • The Generic Scan also allows to determine the E-field amplitude anywhere with a one plane measurement
  • The user can create test channels at any frequency
  • The grid settings are now more open, allowing more flexible and user-friendly operation of the software
  • The measurement grid can now be previewed for all scan types
  • The power density results for different averaging areas can now be visualized simultaneously
  • Completed measurements can be re-evaluated with different communication systems
  • The computation time to post-process scans has been speeded up by x4 on average
  • The report generator, in particular the screenshot functionality, has been improved
  • The measured data can now be exported at any grid resolution
  • The power density viewers show now the location of psSavg

New Generic 2D Scan

The new Generic 2D Scan is used to compute the E-field and estimate the power density on a rectangular two-dimensional grid. The power density value, derived from the E-field distribution without any phase reconstruction, is valid in the far-field only. cDASY6 allows the far-field distance to be determined as function of the antenna radius based on the latest research. This feature dramatically speeds up the time for measurements in the far-field region (by x8 on average).

cDASY6 mmWave Module V1.6 Generic Scan

Power distribution measured with the generic 2D scan in the far field from the source (1-plane)

Custom Test Channels

Custom test channels can be now added in V1.6. This feature allows to test at any frequency even for bands not yet added to the mmWave module.

Grid Settings Flexibility

The flexibility of the grid settings has been greatly improved in V1.6. It is now possible to:

  • Offset the position of the device-under-test relative to the reference point
  • Manually offset and resize the Fast Area Scan grid
  • Define the 5G scan-grid based on the Fast Area Scan

Further, measurements for all scan types can now be previewed.

cDASY6 mmWave Module V1.6 Grid Preview

Grid scan preview with cDASY6 Module mmWave V1.6

Re-Evaluation of Completed Measurements

With V1.6, we have added the possibility to re-evaluate already completed measurements with any communication system. The specificities in hardware (probes, DAE) design do not allow similar re-evaluations based on different hardware components. In these cases, new measurements with the desired hardware must be performed.

Post-Processing

Small but very important improvements to benefit our DASY6 users have been introduced in the post-processing procedure:

  • Power density distributions can now be computed and visualized simultaneously with different averaging areas
  • The computation time for post-processing of scans is on average 4× faster
  • By default, settings in the “options”-view are adjusted to user the needs
  • The measurement data can be exported at any grid resolution

Note that the post-processing algorithm itself has not been modified.

Report Generation

Review of the “report generator”-tool has resulted in the following improvements:

  • The size of the field plot can now be defined by the user for more consistent result reporting
  • The scalar bar is now considerably larger to improve overall readability

cDASY6 mmWave Module V1.6 Report Generator

E-field distribution measured with a 2D-generic scan in the near-field of the source

Improved Power Density Viewers

The power density viewers have been improved based on the feedback we have received from you:

  • The peak averaged power density is displayed with a grey circle
  • The averaged power density plots have now the same size as the measurement grid. The post processing algorithm uses zero padding to compute the averaged power density where the averaging circle would be truncated. This area is delimited by a dashed grey line on the plot. Averaged power density values outside this line might be underestimated and should not be considered as accurate.

cDASY6 mmWave Module V1.6 FRONT 2 00 0 CW 60000 00MHz 3dcDASY6 mmWave Module V1.6 Savg

Power Density S (left) and Averaged Power Density (right). The averaging circle shows the maximum of the averaged power density. Only values inside the dashed line should be considered as accurate

The next major cDASY6 software release, V2.0, will feature two major optional modules:

  • The Optimizer Module for determination of the worst-case power density of antenna arrays from a series of single-element measurements
  • The Forward Transform Evaluation (FTE) Module for evaluation of the power density distribution along any virtual surface (e.g., SAM Head) from a single measurement and estimation of the radiation pattern

For further information, please contact us at info@speag.swiss.

SIMULATION

12/11/2012

Contact
semx-support@speag.swiss

 

MUSAIK v1.3 Release

The MUSAIK and SEMCAD X Team is pleased to announce the release of MUSAIK v1.3, a feature release of Musaik.

 
CORPORATE

08/11/2012

Contact
info@speag.swiss

 

Parents back to school: kids take over

On the 2012 National Future Day, four outstanding girls – Anushka, Chimey, Liza, and Sia, and four exceptional boys – Jechiel, Kilian, Moritz, and Arun joined our research and development teams at IT'IS, SPEAG and ZMT for one day.

 
MEASUREMENT

05/09/2012

Contact
info@speag.swiss

 

iSAR V2.6 Software Release

SPEAG is pleased to announce a new software release iSAR V2.6 that further improves repeatability, absolute accuracy and user friendliness of iSAR Flat, Head and Quad. In the next release, we also plan to include novel features that we are currently developing for cSAR3D.

 
SIMULATION

09/08/2012

Contact
semx-support@speag.swiss

 

SEMCAD X APS Raffle Winner

During the IEEE APS 2012 exhibition, a NVIDIA Tesla C1060 card was given away in a raffle at the SEMCAD X User Meeting.

 
MEASUREMENT

07/08/2012

Contact
info@speag.swiss

 

DASY52.8.2 and SEMCAD X V14.6.6 Software Release

SPEAG is pleased to announce the release of DASY52.8.2 (969) and SEMCAD-X V14.6.6 (6824). It took us slightly longer than promised for this release, however we not only removed the reported bugs but also added new features which will ease the daily usage of our DASY system as well as provide even better compatibility with current and upcoming compliance standards. In particular, we support our new MIF box, support the creation of SAR compliance reports and we improved the interface to the CMW500. In addition, the DAK team added two new videos to our webpage.

 
MEASUREMENT

02/08/2012

Contact
info@speag.swiss

 

New Phantom Products

In response to customer requests for more versatile phantoms, SPEAG introduces several new whole-body and hand phantoms.

 
CORPORATE

24/07/2012

Contact
info@speag.swiss

 

SPEAG sponsors "IT'IS for Health" with CHF 200 000

SPEAG Executive Board congratulates Niels Kuster, SPEAG Co-Founder and President of the Board of Directors, on receiving the distinguished d'Arsonval Award, the highest scientific honor of the Bioelectromagnetics Society.

 
MEASUREMENT

18/07/2012

Contact
info@speag.swiss

 

DAK Software Release

We are pleased to announce the latest DAK Software which is more flexible and versatile than the previous version.

 
SIMULATION

12/07/2012

Contact
semx-support@speag.swiss

 

SEMCAD X v14.8.1 Update Release

The SEMCAD X Team is pleased to announce the release of SEMCAD X v14.8.1, an update of SEMCAD X Aletsch v14.8.

 
MEASUREMENT

11/07/2012

Contact
info@speag.swiss

 

France Enforces SAR Requirements in Limbs

Recent information has been issued by the French government that wireless devices must comply with SAR limits in the limbs and hands. DASY52 is fully compatible with all testing requirements and international measurement standards. SAR phantoms and tissue equivalent liquids are available from SPEAG.

 
Page 18 of 25
 
 
Latest News