Swissmade
NEWS
01/09/2020
MEASUREMENT

cSAR3D V4.0: A Breakthrough in Array System Technology

The new X10 Combiner gives cSAR3D Flat phantoms higher measurement resolution, driving the measurement uncertainty below 30% for any source and extending the frequency range to 10 GHz.

cSAR3D V4.0 marks a major advancement for vector measurement-based array measurement systems: the newly integrated "X10 Combiner", a novel algorithm developed by the IT'IS Foundation that reliably combines multiple randomly shifted individual measurements onto a high-resolution grid, eliminates the physical limitation of the sensor density of fixed arrays by virtually increasing the spatial sampling resolution. As a result, the frequency range of cSAR3D has been extended to 10 GHz and the uncertainty has been reduced to 30% for any source. The timing is perfect as the Federal Communications Commission (FCC) and other regulators have recently opened unlicensed spectrum above 6 GHz and the soon-to-be-published IEC/IEEE Standard 62209-1528 includes SAR measurement procedures up to 10 GHz.

The key new features of cSAR3D V4.0 are:

  • X10 Combiner – novel spatial combining algorithm to give a higher measurement resolution
  • Extended frequency range up to 10 GHz
  • Estimation of absorbed power density (epithelial power density) for comparison with new limits in new ICNIRP guidelines and the IEEE C95.1 standard
  • Even faster measurement time

The user video nicely illustrates these new features and how easy they are to use.

Higher Measurement Resolution

The spatial combining algorithm, called the X10 Combiner, is easy to use and does not require any new equipment. The software guides the user to make multiple measurements with the device at random positions on the cSAR3D Flat. It then automatically determines the shift in the device position from the specific absorption rate (SAR) distribution and uses these shifts to reconstruct the 3D pattern using these high-density measurement points. Thus, the physical resolution can be overcome, allowing measurement of devices having very sharp SAR distributions.

Extended Frequency Range

SPEAG extended the frequency range of DASY6 last year to include the 6 – 10 GHz frequency range and has now done the same for the cSAR3D Flat. This meets the emerging needs of wireless device manufacturers to test Wi-Fi and 5G devices in this frequency range.

No change is needed to the cSAR3D hardware. The miniature sensors inside the phantom have good sensitivity and are electrically small at 10 GHz. The tissue-equivalent medium is already compatible with the requirements for dielectric parameters up to 10 GHz. The only requirement is that the cSAR3D Flat or Quad is re-calibrated to include the 6 – 10 GHz frequency range. Note that SPEAG is now accredited to ISO/IEC 17025 for calibration of cSAR3D Flat and Quad at all frequencies in the 650 MHz – 10 GHz range.

cSAR3D V4.0 leads to a significant accuracy improvement for very localized SAR distributions. The full IEC 62209-3 validation (264 test conditions) has been performed on the cSAR3D Flat using the X10 Combiner as well as single measurements. Additional validation tests have been performed in the 6 – 10 GHz frequency range using the X10 Combiner. The results show that all combined values are within +/-1 dB of the target values indicating that the measurement uncertainty when using the X10 Combiner is less than 30% for any source.

Absorbed power density

Another novelty is that cSAR3D V4.0 also assesses and displays the absorbed power density (also known as epithelial power density in IEEE C95.1) averaged over an area of either 1 cm2 or 4 cm2. These dosimetric limits have been defined by ICNIRP (2020) and IEEE C95.1 (2019) in the frequency range above 6 GHz. It is expected that these new basic restrictions will soon be adopted by regulators.

Faster Measurement

SPEAG has also improved the measurement speed. The assessment time is now 2.6 s including acquisition, evaluation of 3D field reconstruction, calculation of uncertainty, and graphical output of the results. This also improves throughput for quality assurance testing in factory environments. Wireless device manufacturers have implemented cSAR3D for factory sampling due to its speed and automation features.

cSAR3D V4.0, together with the manual, are available for download here.

SIMULATION

22/04/2014

Contact
semx-support@speag.swiss

 

ZMT Zurich MedTech presentation in the ISMRM Product Theater

ZMT Zurich MedTech will exhibit at the ISMRM conference (booth #532) and will participate in the ISMRM Product Theater (booth #444)

 
MEASUREMENT

10/04/2014

Contact
info@speag.swiss

 

DAKS – Dielectric Measurements Made Easier

SPEAG is delighted to announce the release of an improved version of the Dielectric Assessment Kit System (DAKS). With a longer probe and a dedicated trigger button, the new DAKS makes dielectric measurements easier than ever.

 
MEASUREMENT

26/02/2014

Contact
info@speag.swiss

 

SAM-Mask 6 degrees V2

SPEAG Launches New and Improved SAM-MASK 6 DEGREES V2

 

 

 
SIMULATION

29/01/2014

Contact
semx-support@speag.swiss

 

SEMCAD X Matterhorn

 SPEAG and ZMT recently released the internal beta version of SEMCAD X Matterhorn to an enthusiastic reception from our partners.

 

 
CORPORATE

15/01/2014

Contact
info@speag.swiss

 

IT'IS/Speag/ZMT Retreat in Bergün on Winning and Failing Strategies and Mindsets

Twenty-two IT'IS, Speag, and ZMT co-workers retreated for two days, 13 – 14 January 2014, to the Kurhaus Bergün, a grand old Jugendstil-era hotel in the Albula region of canton Graubünden. Their mission: to learn about the strategies and mindsets that impact workplace productivity and success, as well as winning and failing strategies and mindsets implemented by leaders, empires, and industries.

 
CORPORATE

31/12/2013

Contact
info@speag.swiss

 

Successful SPEAG exhibtions and workshops during 2012

SPEAG successfully participated on multiple international conferences and exhibitions during 2012.

 
CORPORATE

13/12/2013

Contact
info@speag.swiss

 

Successful SPEAG Workshops in Tokyo

SPEAG and ZMT held a successful and well-attended hardware & software workshop in Tokyo, Japan on December 13th, 2013.

 
MEASUREMENT

10/12/2013

Contact
info@speag.swiss

 

cSAR3D Production Release

SPEAG is excited to announce the series production of cSAR3D, the next generation in fast and high-precision SAR measurement equipment. We will start shipping in January, increasing to two full cSAR3D systems per month during Q1 2014. In January, we will also have available our extensive cSAR3D performance evaluation and DASY52 comparison study of over 40 wireless devices of different  manufacturers. More information is now available on our product page.

 
SIMULATION

25/11/2013

Contact
semx-support@speag.swiss

 

SEMCAD X v14.8.5 Update Release

The SEMCAD X Team is pleased to announce the release of SEMCAD X v14.8.5, an update of SEMCAD X Aletsch v14.8.

 
MEASUREMENT

21/11/2013

Contact
info@speag.swiss

 

New Product: Hand-Forearm Phantom

SPEAG Announces Release of New Hand-Forearm Phantom for Wrist-Mounted Devices

 