MAGPy customers can rejoice: SPEAG has released MAGPy2, which includes a redesigned probe and extended software. MAGPy2 guarantees accurate extrapolation of incident fields to the probe surface, support of pulsed and multifrequency signals, and estimates of all basic restriction quantities required by regulators. MAGPy2 is fully compatible with IEC/IEEE 63184:2023 and meets all the latest FCC and ISED requirements. MAGPy2 can also be used as part of the measurement system DASY8/6 Module WPT V2.0.
SPEAG released the first version of MAGPy in June 2021. It was designed to carry out reliable in situ compliance testing in the near field of wireless power transfer (WPT) systems or in the close vicinity of high-current industrial installations. The system is the most advanced device on the market, i.e., the only handheld device that reliably estimates basic restriction quantities and that is compatible with IEC/IEEE 63184:2023 Tier 3.
But we wanted to make the system even better, so we have redesigned the probe and extended the software to further boost its performance and its compatibility with the latest regulatory requirements. MAGPy2 with software V2.0 has major benefits:
Measuring closer to the source (7.5 mm vs 20.0 mm) and hence providing much more accurate and reliable extrapolation to the surface of the probe; this empowers field evaluations on the surface of the device under test, as required by FCC (TCB Workshop in April 2022) and ISED (RSS-102 SPR-002 Issue 2 published in October 2022);
Evaluation of periodic signals with non-sinusoidal waveforms and duty cycles, thanks to the implementation of the multifrequency processing algorithm and the peak detection function;
Addition of new basic restriction quantities, i.e., local induced electric (E-) field (required by ISED) and 1 g averaged specific absorption rate (SAR; required by FCC and ISED);
Dual usage of the system as a hand-held system (MAGPy2) and as part of Module WPT (DASY8/6 Module WPT V2.0), resulting in acceleration of the measurement by almost a factor of 8 and additional incident E-field evaluations compared to the first version.
Advantages Compared to Competitive Devices
MAGPy2 is optimized for taking precise measurements of the incident field and the induced fields in the near field of sources:
Its magnetic field sensor has an active area of only 1 cm2 as required by IEC/IEEE 63184:2023 for precise measurements;
The close distance of the measurement sensors to the probe surface combined with gradient information empowers accurate extrapolation to the probe surface;
It is the only device able to estimate the following induced field quantities for Tier 3 assessment as specified in IEC/IEEE 63184:2023 using the gradient information from the 27 sensors:
maximum induced E-field averaged over 8 mm3 (e.g., ICNIRP 2010, ICNIRP 2020)
maximum induced E-field averaged over 5 mm (e.g., IEEE C95.1-2019)
maximum local induced E-field (e.g., HC Safety Code 6)
maximum induced current density averaged over 1 cm2 (e.g., ICNIRP 1998)
peak SAR averaged over 1 g of tissue (e.g., FCC, HC Safety Code 6)
peak SAR averaged over 10 g of tissue (e.g., ICNIRP 1998, ICNIRP 2020, IEEE C95.1-2019)
The evaluation of the basic restriction using the gradient information reduces overestimation of the compliance values by up to 40 dB in the near field of sources compared to standard isotropic probes (a factor of 100 for E-field and current density and a factor of 10,000 for SAR);
It allows entire recorded measurement sessions to be replayed, including post-measurement analyses and evaluations;
It can be upgraded to DASY8/6 Module WPT V2.0 for dual usage without hardware replacement and new calibration.
The video shows a first glimpse of the new probe design and the new features of MAGPy2.
Applications
MAGPy2 is optimized for in situ exposure and compliance evaluations at any location, including:
Automotive/vehicular/train wireless power transfer;
Industrial and utility (e.g., industrial welding, induction cooking, electronic article surveillance, and WPT);
Energy supply (e.g., installations and operators of WPT networks);
Ubiquitous devices equipped with WPT technologies (e.g., mobile phones, implantable medical devices, wearable devices, and Internet of Things);
High power/current electromagnetic sources.
To receive a quotation and for further information, please contact us at info@speag.swiss or via any of our sales channels.
The National Research Council Institute for Biodiagnostics (NRC-IBD) has teamed up with SPEAG to offer a unique software platform for magnetic resonance imaging (MRI) scanner design. The new platform seamlessly integrates powerful new tools for radiofrequency (RF) array design and post-processing and is the first software of its kind to combine all the tools needed to design RF-phased arrays into a single user friendly program.
This new product PRE - 10 is a 3 channel voltage divider which extends the operation of existing SPEAG probes for use in very high fields (> 5 kV/m; > 10 kW/kg). It is compatible with all our E-Field, H-field and SAR probes.
Schmid & Partner Engineering AG (SPEAG) is pleased to announce a new partnership with Telprom, who will be responsible for selling SEMCAD X in Milano, Italy.
The SEMCAD X Team is pleased to announce the release of SEMCAD X V14.2 Aletsch, a major upgrade six months of intense deincorporatingvelopment work. This release offers a range of powerful new features, more robust handling, as well as new customization options.
The relevant SEMCAD X for Win XP/ Win 7 and 32/64bit platforms are available for download.
The new EASY4 software release V4.6 extends the usage to fields with large peak-to-average (PAR) ratios by adaption to the improved probe modulation signal calibration and also includes setting of Access Levels. The changes to the user interface are minimal and old setup and calibration files are still compatible with this version.
A new iSAR2 software release is now available. This release is the result of the popularity of our ultra-fast SAR scanners (iSAR Head and iSAR Flat) and great suggestions from our customers. Version 2.1 of the iSAR software has several new features, including a new multi-iSAR interface, a smart Combiner feature, and full extension of the software for frequencies up to 6 GHz. It also includes enhancements to our existing features, such as an improved Python interface and enhanced control of the CMU200.
Schmid & Partner Engineering AG (SPEAG) is pleased to announce a new partnership with Beacon Technical Sales, Inc., who will be acting as a distributor of SEMCAD X in Nashua, U.S.A.
Zurich Med Tech, a sister company of SPEAG, has developed iSEG, a medical image segmentation tool specially designed to construct realistic 3D human or animal models for SEMCAD X from medical image data. iSEG, the most versatile medical image segmentation tool currently available, quickly and easily creates highly detailed 3D human or animal models based on CT and MRI images in standard image formats. The resulting models can be used to study electromagnetic exposure and induced heating in living tissue.
This website applies cookies to personalize your experience and to make our site easier to navigate. By visiting the site, you are agreeing to this use and to our Privacy Policy.