Swissmade
NEWS
18/05/2021
MEASUREMENT

First DASY8 System Shipped

SPEAG’s next generation modular electromagnetic near-field scanning platform DASY8 has been released with important new features. In addition, the software of three DASY8 Modules has been released, namely Module SAR V16.0, Module mmWave V2.4, and Module WPT V1.2. Module HAC2019, Module R&D, and the DASY8-3D extension will follow later this summer.

SPEAG has released DASY8!

Our new flagship measurement system is based on DASY6 and has been further optimized for both compliance testing and R&D measurements. It provides:

  • the greatest flexibility possible and simplified use thanks to its modular software;
  • faster measurements and enhanced evaluations with improved precision and less overestimation;
  • extended application program interfaces (API) for workflow automation;
  • easy adaptation for emerging technologies.
DASY8 SAR web

DASY8 Module SAR V16.0, Module mmWave V2.4, and Module WPT V1.2 have also been released and come with important new features, as listed below. They will also be made available for DASY6 users soon.

Precise and Flexible Hardware for Quicker Measurements

DASY8 is centered around Stäubli’s new high precision 6-axis robotic arm, the TX2 series, which provides the ideal combination of speed, rigidity, size, and accuracy. The Mounting Platforms (MP8) have been redesigned to provide improved mechanical rigidity and flexibility at the same time. The phantoms are now detachable and fixed at the correct location using a smart locking mechanism.

The robot arm is now interfaced with a new Quick Adapter Change System (QACSV1) that allows fast (<5s) and easy reconfiguration of the system, i.e., a change of probe system (DAE, MAGPy-DAS, third-party probes, etc.) or mounting the device positioner of DASY8-3D. The Electrical to Optical Converter (EOC8) further provides all interfaces (USB, Ethernet) for the entire functionality of the various modules. The Measurement Server (MS8) has increased computation power, enabling smarter planning of robot movements to further reduce measurement time.

Application-Specific Software Modules

The DASY8 software has five different modules. Each module has been optimized for a specific application:

  • Module SAR is optimized to demonstrate compliance with local and whole-body Specific Absorption Rate (SAR) limits from 4 MHz to 10 GHz and Absorbed Power Density (APD) from 6 GHz to 10 GHz;
  • Module mmWave is optimized to demonstrate compliance with the incident PD limits from 6 GHz to 110 GHz as close as 2 mm from the Equipment Under Test (EUT);
  • Module WPT is optimized to demonstrate compliance of magnetic field sources (e.g., wireless power transfer (WPT)) operating from 3 kHz to 4 MHz with reference levels limits and basic restrictions;
  • Module HAC2019 is optimized to effectively demonstrate hearing aid compatibility (HAC) with IEEE C63.19-2019;
  • Module R&D is optimized to perform user-specific scans and data processing with SPEAG's own probes as well as those of third parties.

Two additional DASY8 products will be released later this year:

  • DASY8-3D, which combines the speed of cSAR3D with the precision and versatility of DASY8;
  • DASY8 Module AIMD (Active Implantable Medical Devices) from our partner company ZMT Zurich MedTech AG.

All modules include the latest and most advanced high-performance-computing (HPC) enabled reconstruction and evaluation algorithms of Sim4Life. SPEAG is committed to continuing to bridge the gap between measurements and simulations to create even more powerful compliance and R&D tools.

Module SAR V16.0: Easy Multi-TX Evaluations

SPEAG has rewritten the SAR postprocessor to semi-automate the evaluation of a device that can transmit on multiple bands simultaneously. The measurements can be performed on different DASY6 and/or DASY8 systems. Combining SAR results from different bands is done via postprocessing only, i.e., without the need for additional measurements. This has proven to be the most efficient workflow to prove compliance without any significant overestimation. Check out the video below to experience how easy Multi-TX evaluations have now become:

The most important new features and improvements of Module SAR V16.0 are:

  • Extended API option for the further automation of measurements. The scanning commands now support additional parameters such as EUT offsets. The set of tutorials has been reviewed and the examples have been made more interactive;
  • Improved probe sensor linearization verification using our Modulation and Audio Interference Analyser (MAIA);
  • Simplified handling of Tissue Simulating Liquids (TSL) for measurements in the 6 GHz to 10 GHz frequency range;
  • Modernized Graphical User Interface (GUI).

Module mmWave V2.4

Besides including various bug fixes, the postprocessing algorithms of Module mmWave V2.4 have been updated to the latest version of Sim4Life V6.2 so that cubic evaluations as required by the Japanese regulators are possible in addition to spherical ones.

 DASY8 mmWave detail web

The upcoming release, Module mmWave V3.0, will also offer a reconstruction of equivalent sources on the outer shell model of the devices. The device model can be created as a simplified device or imported as a computer aided design (CAD) model of the actual device. This means that evaluations are now also possible for non-planar surfaces and at distances closer than λ/5, overcoming two of the major limitations that existed so far. Furthermore, the new procedure will simplify the testing.

Module WPT V1.2

SPEAG also released DASY8 Module WPT V1.2 which further simplifies compliance testing of small to medium sized magnetic field sources by providing:

  • Flexible volume scan options for various types of magnetic field sources;
  • Easy setup of the EUT, probe positing and improved saving/restoring options;
  • Improved performance for grid creation and visualization and advanced notification options (e.g., estimation of scan size, duration, etc.).

For further information, please contact us at info@speag.swiss or any of our sales channels.

 

MEASUREMENT

18/01/2010

Contact
info@speag.swiss

 

iSAR² V2.1 Software Release

A new iSAR2 software release is now available. This release is the result of the popularity of our ultra-fast SAR scanners (iSAR Head and iSAR Flat) and great suggestions from our customers. Version 2.1 of the iSAR software has several new features, including a new multi-iSAR interface, a smart Combiner feature, and full extension of the software for frequencies up to 6 GHz. It also includes enhancements to our existing features, such as an improved Python interface and enhanced control of the CMU200.

 
SIMULATION

01/01/2010

Contact
semx-support@speag.swiss

 

Events & Exhibitions in 2010

Meet SPEAG engineers at the following forthcoming major conferences, symposia and workshops in 2010

 
SIMULATION

10/11/2009

Contact
info@speag.swiss

 

Beacon Technical Sales, Inc. as New Distributor in U.S.A.

Schmid & Partner Engineering AG (SPEAG) is pleased to announce a new partnership with Beacon Technical Sales, Inc., who will be acting as a distributor of SEMCAD X in Nashua, U.S.A.

 
SIMULATION

23/10/2009

Contact
info@speag.swiss

 

iSEG V3.1 Release

Zurich Med Tech, a sister company of SPEAG, has developed iSEG, a medical image segmentation tool specially designed to construct realistic 3D human or animal models for SEMCAD X from medical image data. iSEG, the most versatile medical image segmentation tool currently available, quickly and easily creates highly detailed 3D human or animal models based on CT and MRI images in standard image formats. The resulting models can be used to study electromagnetic exposure and induced heating in living tissue.

 
MEASUREMENT

16/10/2009

Contact
info@speag.swiss

 

Final Release DASY52

The final release of DASY52 is a major upgrade representing the next leap in quality compliance testing of mobile phones and general near-field evaluations. The main new improvements are in the new GUI, Report Generator, Ultra-Fast SAR Procedures, and Advanced Probe Response Linearization.  Many more features that make the system compatible with the revised standards are expected to be released by the end of the year.

 
MEASUREMENT

12/10/2009

Contact
info@speag.swiss

 

Successful CTIA Audits of SPEAG Head and Hand Phantoms

SPEAG OTA phantoms with accessories were successfully tested during first CTIA V3.0 audits at ETS Lindgren, Austin on October 1st and Qualcomm, San Diego on October 9th.

 
MEASUREMENT

25/09/2009

Contact
info@speag.swiss

 

iSAR² Calibration is ISO/IEC 17025 Accredited

Schmid & Partner Engineering AG (SPEAG) is now accredited for iSAR calibration to the rigorous ISO/IEC 17025 quality standards. ISO/IEC 17025 is a laboratory quality standard that is widely recognized internationally. The addition of iSAR calibration to the SPEAG quality system provides a large portfolio of products for which SPEAG provides accredited calibration.

 
SIMULATION

17/08/2009

Contact
info@speag.swiss

 

Dellsoft as New SEMCAD X Reseller in India

Schmid & Partner Engineering AG (SPEAG) is pleased to announce a new partnership with Dellsoft Technologies, who will now act as a reseller of SEMCAD X in India. Dellsoft is a leading technical software company in India. Dellsoft's vision is to  achieve international standards of excellence and to be the leading supplier of technical software, learning programs, and other teaching platforms. Many years of experience in the software business and a strong technical support team will facilitate their efforts in providing SEMCAD X to companies in India. 

 
SIMULATION

06/07/2009

Contact
info@speag.swiss

 

SEMCAD X Student Research Award 2008 Winner Presentations

The SEMCAD X Student Research Award for 2008 prizes were presented to the winners during the June 2009 IEEE International Symposium on Antennas and Propagation (APS/URSI), in Charleston, SC, USA.

 
SIMULATION

01/07/2009

Contact
semx-support@speag.swiss

 

SEMCAD X Student Research Award 2008 Winners

Schmid & Partner Engineering AG (SPEAG) is very pleased to announce the winners of SEMCAD X Student Research Award 2008.

 
Page 29 of 30
 
 
Latest News